Table 6. UNIX LLI driver messages for the Ethernet
controller
pnt0-6
Cannot allocate memory for the adapter
during an interrupt. Please check the
Streams parameters.
Explanation: On a SunSoft Solaris system,
this message indicates that the system is out of
Streams memory blocks.
Action: Use the CRASH utility to increase the
number of Streams memory blocks. Modify the
interrupt request (IRQ) settings in the
Configuration/Setup Utility program, or run the
NETCONFIG program to match the hardware
settings.
pnt0-7
Cannot allocate memory for the adapter
during reset. Please check the Streams
parameters.
Explanation: The system is out of Streams
memory blocks.
Action: Use the CRASH utility to increase the
number of Streams memory blocks.
pnt0-11
Device not found!
Explanation: The driver cannot find an
Ethernet controller.
Action: Verify that the Ethernet controller is
enabled. If the Ethernet controller is enabled,
run the diagnostic programs.
pnt0-12
Device failed checksum test!
Explanation: The driver cannot find an
Ethernet controller.
Action: Verify that the Ethernet controller is
enabled. If the Ethernet controller is enabled,
run the diagnostic programs.
pnt0-13
add_intr_handler failed! Interrupts already
enabled.
Explanation: The interrupt request (IRQ) that
was specified, or the IRQ that was found,
conflicts with other devices in the server.
Action: Modify the hardware settings.
pnt0-14
Cannot locate hardware.
Explanation: The SunSoft Solaris driver
cannot find any Ethernet controller.
Action: Verify that the Ethernet controller is
enabled. If the Ethernet controller is enabled,
run the diagnostic programs.
Diagnostics
39