IBM 6000R - Netfinity - 8682 Hardware Maintenance Manual page 176

Hardware maintenance manual
Hide thumbs Also See for 6000R - Netfinity - 8682:
Table of Contents

Advertisement

Error
Code/Symptom
180-XXX-004
(Failed Processor
LED test)
180-XXX-005
(Failed SCSI
Backplane LED
test)
180-XXX-006
(Memory Board
LED test)
201-XXX-0NN
(Failed Memory
test, see "Memory
Settings" on page
47.) NN = DIMM
location.
201-XXX-999
(Multiple DIMM
failure, see error
text.)
202-XXX-001
(Failed System
Cache test)
202-XXX-002
(Failed System
Cache test)
202-XXX-003
(Failed System
Cache test)
202-XXX-004
(Failed System
Cache test)
206-XXX-000
(Failed Diskette
Drive test)
215-XXX-000
(Failed IDE CD-
ROM test)
217-XXX-000
(Failed BIOS Fixed
Disk test)
Note: If RAID is
configured,
the fixed
disk number
refers to the
RAID logical
array.
164
Netfinity 6000R Type 8682 Models 1RY, 2RY
FRU/Action
1. System Board
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
1. Memory Board
2. System Board
1. DIMM Location J1-J16
2. Memory card
1. See error text for failing
DIMMs
2. Memory card
1. Microprocessor CPU 1
1. Microprocessor CPU 2
1. Microprocessor CPU 3
1. Microprocessor CPU 4
1. Cable
2. Diskette Drive
3. System Board
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
1. Fixed Disk 1

Advertisement

Table of Contents
loading

Table of Contents