IBM 6000R - Netfinity - 8682 Hardware Maintenance Manual page 175

Hardware maintenance manual
Hide thumbs Also See for 6000R - Netfinity - 8682:
Table of Contents

Advertisement

Error
Code/Symptom
035-253-S99
(RAID adapter
initialization failure)
075-XXX-000
(Failed Power
Supply test)
089-XXX-001
(Failed
Microprocessor
test)
089-XXX-002
(Failed Optional
Microprocessor
test)
089-XXX-003
(Failed Optional
Microprocessor
test)
089-XXX-004
(Failed Optional
Microprocessor
test)
165-XXX-000
(Failed Service
Processor test)
180-XXX-000
(Diagnostics LED
failure)
180-XXX-001
(Failed information
LED panel test)
180-XXX-002
(Failed Diagnostics
LED Panel test)
180-XXX-003
(Failed System
Board LED test)
FRU/Action
1. ServeRAID Adapter in slot S
is not configured properly.
Obtain the basic and extended
configuration status and refer
to the ServeRAID Hardware
Maintenance Manual for more
information.
2. Cable
3. SCSI Backplane
4. Adapter
1. Power Supply
1. Microprocessor
1. Optional Microprocessor 2
1. Optional Microprocessor 3
1. Optional Microprocessor 4
1. Service Processor Board.
2. System Board. Before
replacing the System Board,
ensure that System Board
jumper J5 is not installed (the
default) when the error occurs.
1. Run Diagnostic LED test for
the failing LED.
1. Information LED Panel
2. Diagnostic LED Panel
3. System Board
1. Diagnostics LED Panel
2. System Board
1. System Board
Symptom-to-FRU index
163

Advertisement

Table of Contents
loading

Table of Contents