POST error codes

In the following error codes, X can be any number or letter.
Error
Code/Symptom
062
(Three consecutive
boot failures using
the default
configuration.)
Description
Standby
mode or dc
problem.
Power is OK.
1. Run Configuration/Setup
2. Battery
3. System Board
4. Processor
FRU/Action
1. Move jumper on
J19 to pins 2-3 to
bypass power
control. If the DC
Good LED comes
on, press
Ctrl+Alt+Delete.
Watch the screen
for any POST
errors. Check the
System Error Log
for any listed
problems.
If the system
powers up with no
errors:
a. Diagnostic
2. Remove the
adapters and
disconnect the
cables and power
connectors to all
internal and
external devices.
Power-on the
system. If the DC
Good LED comes
on, replace the
adapters and
devices one at a
time until you
isolate the
problem.
3. Power Supply
4. Power Backplane
5. System Board
N/A
FRU/Action