IBM 6000R - Netfinity - 8682 Hardware Maintenance Manual page 168

Hardware maintenance manual
Hide thumbs Also See for 6000R - Netfinity - 8682:
Table of Contents

Advertisement

Beep/Symptom
3-2-3
(Math
coprocessor
failed)
3-2-4
(Failure
comparing
CMOS memory
size against
actual)
3-3-1
(Memory size
mismatch
occurred, see
"Memory
Settings" on
page 47)
3-3-2
(Critical SMBUS
error occurred)
(I2C bus error)
3-3-3
(No operational
memory in
system)
Two Short
Beeps
(Information
only, the
configuration
has changed)
Three Short
Beeps
One
Continuous
Beep
156
Netfinity 6000R Type 8682 Models 1RY, 2RY
1. Optional processor (if
installed)
2. Processor
3. System board
1. DIMM
2. Battery
3. System board
1. DIMM
2. System board
3. Battery
1. Disconnect the server power
cord from outlet, wait 30
seconds and retry.
2. System Board
3. DIMMs
4. Memory Card
5. DASD Backplane
6. Power Supply
7. Power Supply Backplane
8. 12C Cable
1. Install or reseat the memory
modules, then do a 3 boot
reset. (See "Using the
Configuration/Setup Utility
program" on page 43.)
2. DIMMs
3. Memory Card
4. System Board
1. Run Diagnostics
2. Run Configuration/Setup
1. DIMM
2. System Board
1. Processor
2. Optional Processor (if installed)
3. System Board
4. Service Processor Card
FRU/Action

Advertisement

Table of Contents
loading

Table of Contents