Error
Code/Symptom
001-XXX-000
(Failed core tests)
001-XXX-001
(Failed core tests)
001-250-000
(Failed System
Board ECC)
001-250-001
(Failed System
Board ECC)
005-XXX-000
(Failed Video test)
011-XXX-000
(Failed COM1
Serial Port test)
011-XXX-001
(Failed COM2
Serial Port test)
014-XXX-000
(Failed Parallel
Port test)
015-XXX-001
(Failed USB test)
015-XXX-015
(Failed USB
External Loopback
test)
015-XXX-198
(USB device
connected during
USB test)
020-XXX-000
(Failed PCI
Interface test)
020-XXX-001
(Failed Hot-Swap
Slot 1 PCI Latch
test)
020-XXX-002
(Failed Hot-Swap
Slot 2 PCI Latch
test)
FRU/Action
1. System Board
1. System Board
1. System Board
1. System Board
1. Video Adapter (if installed)
2. System Board
1. System Board
1. System Board
1. System Board
1. System Board.
1. Make sure parallel port is not
disabled.
2. Re-run USB External
Loopback test.
3. System board.
1. Remove USB devices from
USB1 and USB2.
2. Re-run test.
3. System Board.
1. System Board
1. PCI Hot-Swap Latch
Assembly
2. System Board
1. PCI Hot-Swap Latch
Assembly
2. System Board
Symptom-to-FRU index