Table 4. NDIS 2.01 (OS/2) driver messages for the Ethernet
controller
PCNTND-10
PCNTND-11
PCNTND-15
PCNTND-16
PCNTND-21
PCNTND-23
36
Netfinity 6000R Type 8682 Models 1RY, 2RY
The Protocol Manager Input Output
Control (IOCTL) failed.
Explanation: The NDIS stack is not
configured correctly in the
PROTOCOL.INI file.
Action: Check and correct the
configuration.
Protocol Manager registration failed.
Explanation: The NDIS stack is not
configured correctly.
Action: Check and correct the
configuration.
Device not found.
Explanation: The driver cannot find an
Ethernet controller in the server.
Action: Verify that the Ethernet controller
is enabled. If the Ethernet controller is
enabled, go to "Starting the diagnostic
programs" on page 17 to run the
diagnostic programs.
PCI scan specified, device not found.
Explanation: The driver cannot locate
the Ethernet controller on the PCI bus.
Action: Verify that the Ethernet controller
is enabled. If the Ethernet controller is
enabled, go to "Starting the diagnostic
programs" on page 17 to run the
diagnostic programs.
The adapter failed the checksum test.
Explanation: The driver cannot find an
Ethernet controller.
Action: Verify that the Ethernet controller
is enabled. If the Ethernet controller is
enabled, go to "Starting the diagnostic
programs" on page 17 to run the
diagnostic programs.
WARNING: PCNET IRQ found = xx
Explanation: The interrupt request (IRQ)
setting (
) in the PROTOCOL.INI file
xx
does not match the hardware IRQ setting.
Action: Remove the IRQ setting from the
PROTOCOL.INI file or change the IRQ
setting in the PROTOCOL.INI file to
match the IRQ setting shown in the PCI
Slot/Device Information selection of the
Advanced Setup menu in the
Configuration/Setup Utility program.