General
CD-ROM drive is
not recognized.
Power switch does
not work and reset
button does work.
Front panel is not
plugged in.
On/Off Reset panel
is not plugged in.
CD-ROM drive
cable is not
plugged in.
Diskette drive in-
use light stays on,
or the system
bypasses the
diskette drive, or
the diskette drive
does not work.
FRU/Action
1. Run Configuration/Setup,
enable primary IDE
channel.
2. Check cables and jumpers.
3. Check for correct device
driver.
4. Run CD-ROM diagnostics.
5. CD-ROM drive
6. System Board
1. Verify that the power-on
control jumper on J19 is on
pins 1 and 2.
2. Power Switch Assembly
3. System Board
1. Make sure front panel is
plugged in.
1. Make sure On/Off Reset
panel is plugged in.
1. Make sure CD-ROM drive
cable is plugged in.
1. If there is a diskette in the
drive, verify that:
a. The diskette drive is
enabled in the
Configuration/Setup
utility program.
b. The diskette is good
and not damaged. (Try
another diskette if you
have one.)
c. The diskette is inserted
correctly in the drive.
d. The diskette contains
the necessary files to
start the server.
e. The software program is
OK.
f. Cable is installed
correctly (proper
orientation)
2. Run Diskette Drive
Diagnostics.
3. Cable
4. Diskette Drive
5. System Board
Symptom-to-FRU index
167