Advertisement

Message
System over
recommended ambient
temperature
(level-warning; ambient
temperature too warm for
safe system operation)

Fan error messages

Message
Fan "X" fault (level-
critical; fan "X" beyond
recommended RPM
range)

Power error messages

Message
Power supply "X" DC
good fault (level-critical;
power good signal not
detected for power supply
"X")
Power supply "X" fan fault
(level-critical; fan fault in
power supply "X")
Power supply "X" fault
(level-critical; overcurrent
condition exists)
Power supply "X" 12V
fault (level-critical;
overcurrent condition
detected)
Power supply "X" 3.3V
fault (level-critical; 3.3V
power supply "X" had an
error)
Power supply "X" 5V fault
(level-critical; 5V power
supply "X" had an error)
Power supply current
exceeded max spec value
(level-critical; current draw
in system is over allowance
for a single supply)
Action
1. Ambient temperature
must be within normal
operating
specifications; (see
"Features and
specifications" on page
3).
Action
1. Check connections to
fan "X"
2. Replace fan "X"
Action
1. Replace power
supply "X"
1. Replace power
supply "X"
1. See "Power
checkout" on page
23.
1. See "Power
checkout" on page
23.
1. See "Power
checkout" on page
23.
1. See "Power
checkout" on page
23.
1. See "Power
checkout" on page
23.
Symptom-to-FRU index