hard disk drives. You can also cable a ServeRAID adapter
to external hard disk drives.
Notes:
1. The illustrations in this document might differ slightly
from your hardware.
2. Refer to the documentation that comes with your
adapter for any cabling instructions.
3. Cable identifiers are printed on the cables that come
with the server and options. Use these identifiers to
connect the cables to the correct connectors. For
example, the hard disk drive cables are labeled HDD.
To cable the ServeRAID adapter:
1. Turn off the server.
2. Remove all adapters from the Active PCI adapter slots.
3. Remove the plastic dividers between the PCI adapter
slots.
4. Press the fan assembly release latches on both sides
of the fan assembly; then, remove the fan assembly
from the server.
1
Plastic dividers
2
Fan assembly release latch
3
ServeRAID adapter
5. Disconnect the internal SCSI cable from the SCSI con-
nector (J38) on the system board. (See "System board
cable connectors" on page 55).
6. Carefully thread the disconnected end of the internal
SCSI cable out of the chassis, pulling the cable out of
the opening in the chassis.