Scsi Error Codes - IBM 6000R - Netfinity - 8682 Hardware Maintenance Manual

Hardware maintenance manual
Hide thumbs Also See for 6000R - Netfinity - 8682:
Table of Contents

Advertisement

Message
Failure reading I2C device.
Check devices on bus 9.
Failure reading I2C device.
Check devices on bus 9.
Failure reading I2C device.
Check devices on bus 9.

SCSI error codes

Error Code
All SCSI Errors One or
more of the following might
be causing the problem:
• A failing SCSI device
(adapter, drive,
controller)
• An improper SCSI
configuration or SCSI
termination jumper
setting
• Duplicate SCSI IDs in
the same SCSI chain
• A missing or improperly
installed SCSI
terminator
• A defective SCSI
terminator
• An improperly installed
cable
• A defective cable
Action
1. Reseat DIMMs 5, 6, 7l,
and 8
2. Replace DIMMs 5, 6,
7l, and 8
3. Replace memory card
4. Replace System Board
1. Reseat DIMMs 9, 10,
11, and 12
2. Replace DIMMs 9, 10,
11, and 12
3. Replace memory card
4. Replace System Board
1. Reseat DIMMs 13, 14,
15, and 16
2. Replace DIMMs 13,
14, 15, and 16
3. Replace memory card
4. Replace System Board
FRU/Action
1. External SCSI
devices must be
powered-on before
you power-on the
server.
2. The cables for all
external SCSI
devices are
connected correctly.
3. If you have attached
an external SCSI
device to the server,
make sure the
external SCSI
termination is set to
automatic.
4. The last device in
each SCSI chain is
terminated correctly.
5. The SCSI devices
are configured
correctly.
Symptom-to-FRU index
181

Advertisement

Table of Contents
loading

Table of Contents