Dasd Checkout; Cpu Checkout; Undetermined Problems - IBM 6000R - Netfinity - 8682 Hardware Maintenance Manual

Hardware maintenance manual
Hide thumbs Also See for 6000R - Netfinity - 8682:
Table of Contents

Advertisement

Message
System shutoff due to
faults on each supply
(level-critical; each installed
power supply encountered a
fault condition)

DASD checkout

Message
Hard drive "X" removal
detected (level-critical; hard
drive "X" has been removed)
Hard Drive (SCSI ID "X")
fault (level-critical; error has
occurred on a DASD drive in
a RAID configuration
causing it to be defunct)

CPU checkout

Message
Host BIST fail (level-
informational; host's built-in
self test failed)
Internal Error CPU "X"
fault (level-critical; specified
processor reported internal
error and is held offline and
system restarted)

Undetermined problems

You are here because the diagnostic tests did not identify
the failure, the Devices List is incorrect, or the system is
inoperative.
Note: A corrupt CMOS can cause undetermined problems.
Check the LEDs on all the power supplies, see"Power sup-
ply LED errors" on page 170. If the LEDs indicate the power
supplies are working correctly, return here and do the follow-
ing:
1. Power-off the computer.
2. Be sure the system is cabled correctly.
186
Netfinity 6000R Type 8682 Models 1RY, 2RY
Action
1. See "Power
checkout" on page
23.
Action
1. Information only,
take action as
appropriate.
1. Ambient
temperature must
be within normal
operating
specifications (see
"Features and
specifications" on
page 3.
Action
1. Reseat CPU
2. Replace CPU
1. If problem persists,
replace CPU "X".