IDE DVD-ROM drive test error codes

Error Code/Explanation
1900h (Critical/Command Error.)
1901h (DVD Seek Test failed.)
1902h (DVD Read Test failed.)

SCSI test error codes

Code/Explanation
0500h (SCSI device not ready.)
0502h (SCSI device read error.)
0506h (SCSI disk self test failed.)
0507h (SCSI disk buffer error.)
0508h (SCSI disk random read error.)
FRU/Action
1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.
1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.
1. Replace media.
2. Check drive cables and connections.
3. Connect drive to other IDE channel.
4. Drive.
5. I/O board.
FRU/Action
1. Confirm that drive is configured.
2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.
1. Confirm that drive is configured.
2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.
1. Confirm that drive is configured.
2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.
1. Confirm that drive is configured.
2. Check drive cables and connections.
3. Drive.
4. I/O board or SCSI add-on controller.
1. Confirm that drive is configured.
2. Check drive cables and connections.
3. Drive.
4. System I/O Board or SCSI add-on controller.
Chapter 6. Symptom-to-FRU index