Scsi Error Codes; Temperature Error Messages - IBM xSeries 230 6RY Hardware Maintenance Manual

Table of Contents

Advertisement

SCSI error codes

Error Code
All SCSI Errors One or more of the
following might be causing the problem:
v A failing SCSI device (adapter, drive,
controller)
v An improper SCSI configuration or SCSI
termination jumper setting
v Duplicate SCSI IDs in the same SCSI
chain
v A missing or improperly installed SCSI
terminator
v A defective SCSI terminator
v An improperly installed cable
v A defective cable

Temperature error messages

Message
DASD "X" Over Temperature
(level-critical; Direct Access Storage Device
bay "X" was over temperature)
DASD "X" Over recommended
Temperature (level-warning; DASD bay
"X" had over temperature condition)
DASD "X" under recommended
temperature (level-warning; direct access
storage device bay "X" had under
temperature condition)
DASD 1 Over Temperature (level-critical;
sensor for DASD1 reported temperature
over recommended range)
Power Supply "X" Temperature Fault
(level-critical; power supply "x" had over
temperature condition)
System board is over recommended
temperature (level-warning; system board
is over recommended temperature)
System board is under recommended
temperature (level-warning; system board
is under recommended temperature)
System over temperature for CPU "X"
(level-warning; CPU "X" reporting over
temperature condition)
System under recommended CPU "X"
temperature (level-warning; system
reporting under temperature condition for
CPU "X")
140
Hardware Maintenance Manual: xSeries 230 Models 6RY, 61Y
FRU/Action
1. External SCSI devices must be powered-on before you power-on
the server.
2. The cables for all external SCSI devices are connected correctly.
3. If you have attached an external SCSI device to the server, make
sure the external SCSI termination is set to automatic.
4. The last device in each SCSI chain is terminated correctly.
5. The SCSI devices are configured correctly.
Action
1. Ensure system is being properly cooled; see"Temperature
checkout" on page 28.
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 28.
1. Ambient temperature must be within normal operating
specifications; (see"Features and specifications" on page 3.)
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 28.
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 28.
2. Replace Power Supply "X"
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 28.
2. Replace system board
1. Ambient temperature must be within normal operating
specifications; (see "Features and specifications" on page 3.)
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 28.
1. Ambient temperature must be within normal operating
specifications; (see "Features and specifications" on page 3.