Omron CJ1W-C113 - REV 02-2008 Operation Manual page 323

Position control units
Table of Contents

Advertisement

Two-axis Linear Interpolation
Acceleration and
Deceleration Times
Dwell Times
Zones
296
Address
Setting
21F4
03E8
21F5
0000
21F6
07D0
21F7
0000
21F8
0BB8
21F9
0000
21FA
0FA0
21FB
0000
21FC
1388
21FD
0000
21FE
0000
21FF
0000
2200
0000
2201
0000
Note
Addresses other than the above should be set to their default settings (0).
The origin search acceleration and deceleration times will be used for acceler-
ation and deceleration and so this data needs to be set completely to the
default settings (0).
Dwell times are not used in these programs, so this data area needs to be set
completely to the default settings (0).
Zones are not used in these programs, so this data area needs to be set com-
pletely to the default settings (0).
Contents of setting
Position #0
1000 pulses (3E8 Hex)
Position #1
2000 pulses (7D0 Hex)
Position #2
3000 pulses (BB8 Hex)
Position #3
4000 pulses (FA0 Hex)
Position #4
5000 pulses (1388 Hex)
Position #5
0 pulses (0 Hex)
Position #6
0 pulses (0 Hex)