Omron CJ1W-C113 - REV 02-2008 Operation Manual page 133

Position control units
Table of Contents

Advertisement

Examples of Parameter Settings
Parameter Settings
Category
Word
Common
m
Parameters
m + 1
m + 2
m + 3
106
• The operating data area is allocated to the area following the parameter
described above.
• The two axes are controlled.
• A Servo Drive is used for each axis.
• The pulse output method for the two axes is set to CW/CCW output (i.e.,
default setting).
• The two axes operate within the same operating range (1,000 to
1,000,000 pulses).
• The origin proximity signal and origin signal use N.O. contacts (i.e.,
default setting).
• The CW/CCW limit input signals uses N.C. contacts (i.e., default setting).
• Set the default settings using the CX-Programmer.
• Make the following settings for the X axis. Make the same settings for the
Y axis.
• With the following settings, jog operation and direct operation can be per-
formed from the CPU Unit.
• When performing an origin search, make the settings and adjustments
according to each system.
m = D20000 + 100 x unit number
= D20000 + 100 x 0 = D20000
Default Settings and Set Values: Parameters for which individual bits have
specific applications are expressed in hexadecimal (e.g., 0000H).
Name
Operating data area des-
ignation
Beginning word of oper-
ating data area
Axis parameter designa-
tion
Not used.
Default setting
Set value
---
0000H
---
0000H
---
0001H
---
0000H
Section 4-9
Remarks
The operating data area
is allocated between
m+60 and m+99.
Parameters m m+4 to
m+59 are used.