Memory Operation
Program
Operation start
switch
Operation
checking switch
W03000
200213
Busy Flag
200002
200001
W03000
200213
Busy Flag
W03001
W03012
W03014
W03013
W03015
274
W030 is used as a work word.
DIFU
W03002
W03001
200000
W03012
W03002
W03002
W03013
W03014
W03001
W03002
W03002
W03015
W03001
200002
W03000
Takes the rising edge of the
operation start switch.
Takes the status of the
operation start switch.
Sets #0 for the
sequence number.
D00516
Sequence
Enables the
Number Enable
sequence number.
Starts under
operation checking.
Starts under normal
operation.
Starts under
operation checking.
Starts under normal
operation.
INDEPENDENT START
200001
START
Section 10-2
Executed only when
starting the first
time.
Executed when
starting from the
second time
onwards.