Omron CJ1W-C113 - REV 02-2008 Operation Manual page 310

Position control units
Table of Contents

Advertisement

Memory Operation
Speed
Positions
Acceleration and
Deceleration Times
Dwell Times
Zones
Address
Setting
112C
0096
112D
0000
112E
012C
112F
0000
1130
0190
1131
0000
1132
01F4
1133
0000
1134
0000
1135
0000
Note
Addresses other than the above should be set to their default settings (0).
Address
Setting
11F4
03E8
11F5
0000
11F6
05DC
F11F7
0000
11F8
03E8
11F9
0000
11FA
03E8
11FB
0000
11FC
03E8
11FD
000
11FE
000
11FF
000
Note
Addresses other than the above should be set to their default settings (0).
Address
Setting
12BE
0005
12BF
0000
12C0
0014
12C1
0000
12D2
0005
12D3
0000
12D4
0014
12D5
0000
Note
Addresses other than the above should be set to their default settings (0).
Dwell times are not used in these programs, so this data area needs to be set
completely to the default settings (0).
Zones are not used in these programs, so this data area needs to be set com-
pletely to the default settings (0).
Contents of setting
Speed #0
150 pps (96 Hex)
Speed #1
300 pps (12C Hex)
Speed #2
400 pps (190 Hex)
Speed #3
500 pps (1F4 Hex)
Speed #4
0 pps (0 Hex)
Contents of settings
Position #0
1,000 pulses (3E8 Hex)
Position #1
1,500 pulses (5DC Hex)
Position #2
1,000 pulses (3E8 Hex)
Position #3
1,000 pulses (3E8 Hex)
Position #4
1,000 pulses (3E8 Hex)
Position #5
0 pulses (0 Hex)
Contents of settings
Acceleration time #1
Acceleration time #2
Deceleration time #1
Deceleration time #2
Section 10-2
5 ms (5 Hex)
20 ms (14 Hex)
5 ms (5 Hex)
20 ms (14 Hex)
283