Memory Operation
Positioning Sequences
282
Address
Setting
1000
1000
1001
0011
1002
0401
1003
1012
1004
0022
1005
0403
1006
1012
1007
0022
1008
0401
1009
1013
100A
0022
100B
0402
100C
1002
100D
0011
100E
0403
100F
1003
1010
0011
1011
0400
Note
Addresses other than the above should be set to their default settings (0).
Contents of setting
Sequence #0 X axis designation
Output code: 0
Position designation: absolute
Completion code: terminating
Dwell time #0
Acceleration time #1
Deceleration time #1
Initial speed #4
Target speed #1
Sequence #1 X axis designation
Output code: 0
Position designation: relative
Completion code: continuous
Dwell time #0
Acceleration time #2
Deceleration time #2
Initial speed #4
Target speed #3
Sequence #2 X axis designation
Output code: 0
Position designation: relative
Completion code: continuous
Dwell time #0
Acceleration time #2
Deceleration time #2
Initial speed #4
Target speed #1
Sequence #3 X axis designation
Output code: 0
Position designation: relative
Completion code: bank end
Dwell time #0
Acceleration time #2
Deceleration time #2
Initial speed #4
Target speed #2
Sequence #4 X axis designation
Output code: 0
Position designation: absolute
Completion code: continuous
Dwell time #0
Acceleration time #1
Deceleration time #1
Initial speed #4
Target speed #3
Sequence #5 X axis designation
Output code: 0
Position designation: absolute
Completion code: bank end
Dwell time #0
Acceleration time #1
Deceleration time #1
Initial speed #4
Target speed #0