Two-axis Linear Interpolation
Designation of the Operating Data Area
Data Settings
Axis Parameters
Positioning Sequences
294
The operating data area is allocated to D00500 through D00539 by the data
memory settings. In this program example, the operating data area is not set
because it is not used.
The values for D20004 onwards are transferred when the power is turned ON
(or at restart)
Address
Setting
1000
3001
Sequence #0 X, Y axis designation
1001
0000
1002
0100
1003
3001
Sequence #1 X, Y axis designation
1004
0000
1005
0100
1006
3001
Sequence #2 X, Y axis designation
1007
0000
1008
0100
1009
3001
Sequence #3 X, Y axis designation
100A
0000
100B
0100
100C
3001
Sequence #4 X, Y axis designation
100D
0000
100E
0100
Contents of setting
Output code: 0
Position designation for X axis: absolute
Position designation for Y axis: absolute
Completion code: automatic
Dwell time #0/Acceleration time #0/
deceleration time #0
Initial speed #1/Target speed #0
Output code: 0
Position designation for X axis: absolute
Position designation for Y axis: absolute
Completion code: automatic
Dwell time #0
Acceleration time #0
Deceleration time #0
Initial speed #1
Target speed #0
Output code: 0
Position designation for X axis: absolute
Position designation for Y axis: absolute
Completion code: automatic
Dwell time #0
Acceleration time #0
Deceleration time #0
Initial speed #1
Target speed #0
Output code: 0
Position designation for X axis: absolute
Position designation for Y axis: absolute
Completion code: automatic
Dwell time #0
Acceleration time #0
Deceleration time #0
Initial speed #1
Target speed #0
Output code: 0
Position designation for X axis: absolute
Position designation for Y axis: absolute
Completion code: automatic
Dwell time #0
Acceleration time #0
Deceleration time #0
Initial speed #1
Target speed #0
Section 10-4