Omron CJ1W-C113 - REV 02-2008 Operation Manual page 135

Position control units
Table of Contents

Advertisement

Examples of Parameter Settings
Parameter Settings
Category
Word
Common
m
Parameters
m + 1
m + 2
m + 3
108
Note
Operation will be performed for PCUs with unit version 2.0 or earlier. The
emergency stop for the Y axis, however, requires wiring. Some parameter set-
tings will also vary.
• Set the default settings using the CX-Programmer.
• Make the following settings for the X axis.
• With the following settings, jog operation and direct operation can be per-
formed from the CPU Unit.
• When performing an origin search, make the settings and adjustments
according to each system.
m = D20000 + 100 x unit number
= D20000 + 100 x 0 = D20000
Default Settings and Set Values: Parameters for which individual bits have
specific applications are expressed in hexadecimal (e.g., 0000H).
Name
Operating data area des-
ignation
Beginning word of oper-
ating data area
Axis parameter designa-
tion
Not used.
Default setting
Set value
---
0000H
---
0000H
---
1001H
---
0000H
Section 4-9
Remarks
The operating data area
is allocated between to
m+60 and m+99.
Only the X axis is used.
The operating data area
is allocated between
m+4 and m+59.