Forced Interrupt

9-3-6

Timing Chart

Position
(I+8, I+9)
Speed
(I+10, I+11)
Direction designation
(word n, bit 10)
Interrupt feed
(word n, bit 5)
X-axis interrupt input
signal (input to PCU)
Pulse output
Positioning Completed
Flag (word n+8, bit 05)
Busy Flag
(word n+8, bit 13)
9-4

Forced Interrupt

Outline of Operation
Procedure for Using Forced Interrupt
1,2,3...
242
The following timing chart illustrates interrupt feeding under direct operation,
using the X axis for a 4-axis PCU as an example. There is a movement of
10,000 pulses in the direction of travel.
2710 Hex (10000) (Interrupt feeding in the direction of travel)
3E8 Hex (1000)
Speed
FORCED INTERRUPT is a command which is only enabled during memory
operation. It is used for taking emergency evasive action from the current
operation under memory operation.
When a sequence number with the forced interrupt operation set is specified
and the FORCED INTERRUPT Bit is turned ON, the pulse output of the mem-
ory operation currently being executed is stopped (without deceleration) and
positioning is executed from the specified sequence number. There is no need
to turn ON the Sequence Number Enable Bit.
The forced interrupt operation will depend on the startup method at the time of
the interrupt. For operation started with INDEPENDENT START, operation will
follow terminating completion. For any other kind of startup method, operation
will be determined by the completion code in the positioning sequence.
Note
A sequence number error (error code 8101) will be generated in the following
cases.
• If forced interrupt is executed at power up or restart, or after execution of
origin search, origin return, or present position preset.
• If forced interrupt is executed at bank end.
1. Set the forced interrupt action in the positioning sequence and transfer it to
the PCU.
2. When a forced interrupt is required, specify the sequence number set in (1)
and FORCED INTERRUPT from OFF to ON.
10,000 pulses
Section 9-4
Time