Terminal Interface Messages
179
M68340 probe not connected or configured incorrectly
Cause: The emulator is reading an invalid identifier for the emulation probe.
Action: Make sure that the emulator probe cables are connected correctly. Also,
make sure that the probe is the 68340 probe.
179
Fuse F1 blown on HP64748C ABG Control Board
Cause: The emulator detects a blown fuse on the HP 64748C ABG Control Board.
Action: Contact your Hewlett-Packard Representative.

General Emulator and System Messages

204
FATAL SYSTEM SOFTWARE ERROR
205
FATAL SYSTEM SOFTWARE ERROR
208
FATAL SYSTEM SOFTWARE ERROR
Cause: The system has encountered an error from which it cannot recover.
Action: Write down the sequence of commands which caused the error. Cycle
power on the emulator and reenter the commands. If the error repeats, call your
local HP Sales and Service office for assistance.
206
Incompatible compatibility table entry
Cause: The emulation firmware (ROM) is not compatible with the analysis or
system firmware in your HP 64700 system.
Action: The ROMs in your emulator must be compatible with each other for your
emulation system to work correctly. Contact your Hewlett-Packard Representative.
312
Ambiguous address: %s
Cause: Certain emulators support segmentation or function code information in
addressing. The emulator is unable to determine which of two or more address
ranges you are referring to, based upon the information you entered.
Action: Re-enter the command and fully specify the address, including
segmentation or function code information.