Action: Enter the previous trace specification and try again.
Emul700dmn continuation failed
Cause: Communication between the emulator and the host system to continue the
emulation session failed.
Action: Check the data communication switch settings on the rear panel of the HP
64700 series emulator. If necessary, refer to the HP 64700 Installation/Service
Guide.
Emul700dmn executable not found
Cause: The emulation session could not begin because the host system could not
locate the HP 64700 emulator daemon process executable.
Action: Make sure that software installation is correct. Then try starting the
emulator again.
Emul700dmn failed to start
Cause: The emulation session could not begin because the host system could not
start the HP 64700 emulator daemon process.
Action: Make sure there is sufficient disk space under /usr/hp64000. Make sure the
host system is operating properly, that all Softkey Interface software has been
loaded correctly, and the data communication switch settings on the emulator rear
panel match the settings in the /usr/hp64000/etc/64700tab.net (or 64700tab) file.
Emul700dmn message too large
Emul700dmn message too small
Emul700dmn queue and/or semaphores missing
Emul700dmn queue failure
Emul700dmn error in file operation
Emul700dmn queue full
Cause: The HP 64700 emulator daemon process command was too large for the
host system to process.
Action: You must press end_release_system to exit this emulation session
completely; then start a new session. Make sure the host system is operating
properly, that all Softkey Interface software has been loaded correctly, and the data
communication switch settings on the emulator rear panel match the settings in the
436