HP 64751 User Manual page 249

Graphical user interface
Table of Contents

Advertisement

If you wish to combine the windowing and sequencing functions of the analyzer,
there are some restrictions:
Examples
In the demo program, suppose you are only interested in the execution that occurs
within the switch statement of the "combsort" function. You could specify source
line number 228 as the window enable state and the source line number of the next
statement (line number 240) as the window disable state. Set up the windowing
trace specification with the following command.
trace enable main."main.c": line 229 disable
main."main.c": line 241 <RETURN>
set source on <RETURN>
Notice in the resulting trace (you have to press the <NEXT> key) that the enable
and disable states have the "sq adv" string in the line number column. This is
because the windowing feature uses the analyzer's sequencer.
Up to four sequence terms are available when windowing is in effect.
Global restart is not available when windowing is in effect.
Occurrence counts are not available.
Chapter 7: Using the Emulation Analyzer
Using the Sequencer
249