HP 64751 User Manual page 292

Graphical user interface
Table of Contents

Advertisement

Chapter 8: Making Software Performance Measurements
Duration Performance Measurements
From Address
109E
File main(module)."/users/guest/demo/debug_env/hp64751/main.c"
Symbolic Reference at interrupt_sim+8A
To Address
1014
File main(module)."/users/guest/demo/debug_env/hp64751/main.c"
Symbolic Reference at main.interrupt_sim
Number of intervals
Maximum Time 182927.360 us
Minimum Time 82534.400 us
Avg Time
99593.389 us
Statistical summary - for
Stdv 25497.98
95% Confidence 0.99% Error tolerance
Graph of relative percents
1 us 10 us
10.1 us 100 us
100.1 us 500 us
500.1 us 1 ms
1.001 ms 5 ms
5.001 ms 10 ms
10.1 ms
20 ms
20.1 ms
40 ms
40.1 ms
80 ms
80.1 ms
160 ms
160.1 ms 320 ms
320.1 ms 640 ms
640.1 ms 1.2 s
Two sets of information are given in the duration measurement report: module
duration and module usage.
The first set of information in the duration measurement report is the "module
duration" measurement. The module duration report shows that the amount of time
it takes for the interrupt_sim function to execute varies from 65.64 microseconds to
648.4 milliseconds. The average amount of time it takes for the interrupt_sim
module to execute is roughly 67.13 milliseconds.
The second set is the "module usage" measurement. Module usage measurements
show how much time is spent outside the module of interest; they indicate how
often the module is used. The information shown in the first part of the duration
report above shows that the average amount of time spent outside the interrupt_sim
function is about 99.59 milliseconds.
292
2550
10 traces
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
0.00%
96.94%
*************************************************
3.06%
**
0.00%