Chapter 7: Using the Emulation Analyzer
Qualifying Trigger and Store Conditions
Examples
Suppose you want to look at the execution of the demo program after the call of the
"update_system()" function (main.c: line 102) occurs. To trigger on this address,
enter:
trace after address main."main.c": line 102 <RETURN>
set source on inverse_video on symbols on <RETURN>
display trace <RETURN>
In the preceding trace list, line 0 (labeled "after") shows the beginning of the
program loop.
238