To Drive The Emulation Analyzer Trigger Signal To The Bnc Connector; To Break Emulator Execution On Signal From Cmb - HP 64751 User Manual

Graphical user interface
Table of Contents

Advertisement

Chapter 9: Making Coordinated Measurements
Using Trigger Signals
To drive the emulation analyzer trigger signal to
the BNC connector
1 Enter the modify configuration command.
2 Answer "yes" to the "Modify interactive measurement specification?" question.
3 Answer "receive" to the "Should BNC drive or receive Trig1?" question.
You could also drive the emulation analyzer trigger to the BNC over the trig2
internal line by specifying that the BNC should receive trig2 and that the emulation
analyzer should drive trig2.

To break emulator execution on signal from CMB

1 Enter the modify configuration command.
2 Answer "yes" to the "Modify interactive measurement specification?" question.
3 Answer "drive" to the "Should CMBT drive or receive Trig1?" question.
You could also break emulator execution on a trigger signal from the CMB over the
trig2 internal line by specifying that the CMB should drive trig2 and that the
emulator break should receive trig2.
310