HP 64751 User Manual page 468

Graphical user interface
Table of Contents

Advertisement

Chapter 12: Error Messages
Terminal Interface Messages
624
Configuration aborted
Cause: Occurs when a <CTRL>c is entered while emulator configuration items are
being set.
626
Configuration failed; setting unknown: %s=%s
Cause: Target condition or system failure.
Action: Check target system, and run performance verification (Terminal Interface
pv command).
628
Guarded memory break: %s"
Cause: A memory access to a location mapped as guarded memory has occurred
during execution of the user program.
Action: Investigate the cause of the guarded memory access by the user program.
628
Write to ROM break: %s"
Cause: When the emulator is configured to break on writes to ROM, a memory
write access to a location mapped as ROM has occurred during execution of the
user program.
Action: Investigate the cause of the write to ROM by the user program. You can
configure the emulator so that it does not break on writes to ROM.
630
Register access aborted
Cause: Occurs when a <CTRL>c is entered during register display.
631
Unable to read registers in class: %s
Cause: The emulator was unable to read the registers you requested.
Action: To resolve this, you must look at the other status messages displayed.
Most likely, the emulator was unable to break to the monitor to perform the register
read. See message 608.
632
Unable to modify register: %s=%s
Cause: The emulator was unable to modify the register you requested.
468