Terminal Interface Messages

This section contains descriptions of error messages that can occur while using the
Terminal Interface. The error messages are listed in numerical order, and each
description includes the cause of the error and the action you should take to remedy
the situation.
The emulator can return messages to the display only when it is prompted to do so.
Situations may occur where an error is generated as the result of some command,
but the error message is not displayed until the next command (or a carriage return)
is entered.
A maximum number of 8 error messages can be displayed at one time. If more
than 8 errors are generated, only the last 8 are displayed.

Emulator Messages

20
Attempt to change foreground monitor map term
Cause: When configuring the emulator to use a foreground monitor, a memory
range is automatically mapped for the monitor's use. You attempted to alter that
term when mapping memory.
Action: Try using another memory range for the new map term. If you need to
have the range used by the foreground monitor, then switch to a background
monitor, delete the old foreground monitor map term, and add the new term. Now
you can return to using a foreground monitor; remember you will need to reload the
monitor code.
21
Insufficient emulation memory
Cause: You have attempted to map more emulation memory than is available.
Action: Reduce the amount of emulation memory that you are trying to map.
40
Restricted to real time runs
Cause: While the emulator is restricted to real-time execution, you have attempted
to use a command that requires a temporary break in execution to the monitor. The
emulator does not permit the command and issues this error message.
Chapter 12: Error Messages