Chapter 10: Making Coordinated Measurements
Using Trigger Signals
To drive the emulation analyzer trigger signal to
the BNC connector
1 Enter the modify configuration command.
2 Answer "yes" to the "Modify interactive measurement specification?" question.
3 Answer "receive" to the "Should BNC drive or receive Trig1?" question.
You could also drive the emulation analyzer trigger to the BNC over the trig2
internal line by specifying that the BNC should receive trig2 and that the emulation
analyzer should drive trig2.
To drive the external analyzer trigger signal to
the CMB
1 Enter the modify configuration command.
2 Answer "yes" to the "Modify interactive measurement specification?" question.
3 Answer "receive" to the "Should CMBT drive or receive Trig2?" question.
4 Answer "drive" to the "Should External Analyzer drive or receive Trig2?" question.