Routing cables in the cable trough

Installing power bars

P0725810 Issue 3.0
The cable trough beneath the Base Station Module holds the 25-pair
cables, the fiber cables, the power cords, and the power bars. The
cable trough has been designed to keep the power cords and power
bars separate from the 25-pair cables and fiber cables, and to allow
easy access after the installation.
Place the cabling in the two shelves as described in the following
chart:
In the upper shelf:
In the lower shelf:
When you install Line Modules or Base Station Modules with the
Controller, you must use power bars for ac power distribution. There
are two types of power bars: the main power bar, which plugs
directly in the ac outlet, and the expansion power bar, which plugs
into a main power bar. You can connect only one expansion power
bar to a main power bar.
Use the following table to determine how many power bars you
need.
Modules
1–3 (+ Controller)
4–6
7–10
11-12
!
Do not daisy chain more than two power bars.
Daisy chaining more than two power bars compromises the electrical
safety of the product.
COMPANION 200 Installation and Maintenance Guide
Installing the hardware 48
Place the 25-pair cables in the back and the
fiber cables in the front. This shelf is for all 25-
pair cables and fiber cables only.
Place all power cords and power bars only.
Main power bar
1
1
2
2
Expansion power bar
0
1
1
2