Nortel Meridian Companion Installation And Maintenance Manual page 121

Nortel meridian companion: installation guide
Hide thumbs Also See for Meridian Companion:
Table of Contents

Advertisement

Entering the Event/Alarm log
Checking the highest severity alarm
Checking when an alarm or event occurred
Checking consecutive repetitions of an alarm or event
P0725810 Issue 3.0
higher severity number replace existing event messages of a lower
severity. For this reason, check event messages at regular intervals.
You can then deal with all messages before they are replaced.
To enter the Event/Alarm log, follow these steps:
1. Enter a Maintenance session.
2. Press * or & until the display shows
4.Evnt/Alrm Log.
3. Press ^. The display shows Start of new log or
Start of log.
4. Use * or & to scan the alarms and events in
the log (see "Understanding alarm messages" to deal with
alarms).
5. To continue in Maintenance, press % twice.
To check the highest severity alarm, follow these steps:
1. Enter the Event/Alarm log.
2. Press ALARM. The display shows an alarm code if there is an
uncleared alarm, or No current alarm.
3. Press EXIT to return to the Event/Alarm log.
To check when an alarm or event occurred, follow these steps:
1. Enter the Event/Alarm log.
2. Use * or & to scan the alarms and events in
the log.
3. Press TIME at the alarm or event whose time you want to know.
The display shows the date and time that the alarm or event last
occurred, then returns to the alarm.
To check consecutive repetitions of an alarm or event, follow these
steps:
1. Enter the Event/Alarm log.
2. Use * or & to scan the alarms and events in
the log.
3. Press REPEAT at the alarm or event whose number of repetitions
you want to know. The display shows the number of consecutive
COMPANION 200 Installation and Maintenance Guide