P0725810 Issue 3.0
To cross-connect the access lines to the Controller and the Line
Modules, follow these steps:
1. Plug the RJ21 connector of each 25-pair cable into the access
line connector on the Controller and each Line Module. This
connector is identified by an icon of two telephone poles
connected by telephone wires:
2. For each RJ21 connector, turn the RJ21 connector latch so it
covers the connector. Tighten the latch screw to hold the
connector in place.
3. Route the 25-pair cables through the upper shelf of the cable
trough to the distribution frame.
Note: Route the 25-pair cables out of the cable trough in a
bundle. Use cable ties to secure them to the wall and to
support their weight. The cable ties prevent undue stress
on the cable trough shelf when there are several 25-pair
cables.
4. Connect the lines from the Controller to the distribution frame or
frames according to the following Controller access line wiring
chart.
5. Connect the lines from the Line Module(s) to the distribution
frame(s) according to the following Line Module wiring chart.
COMPANION 200 Installation and Maintenance Guide
Installing the hardware 60