3-18 Installation guidelines
Procedure 3-5

Routing the cables to the mounting pad

Use this procedure to route the AN2016 Cabinet cables to the mounting pad.
For an illustration of the cabinet termination end compartment, see
Figure
Requirements
You need the following tools and materials:
Action
Step
1
2
3
4
5
6
7
AN2016 Cabinet User Guide
3-13.
socket wrench set
Action
Remove each nozzle from the cable conduits by loosening the upper hose
clamps (see
Figure
Slip the clamps down the nozzle and remove them.
Set the nozzles and hose clamps safely aside for later reattachment.
Separate the front half of the front split cable sleeve plate by removing the hex
head bolts.
Pull the base plate toward you to remove it (see
Separate the front half of the rear split cable sleeves by removing the two hex
head bolts securing the center base plate (see
Note: Do not disturb the rear half of the rear split cable sleeve as it was
installed and sealed at the factory.
Dress the cables toward the near end of the pad to prepare for installation of
the cabinet.
Rel 1.0 Standard May 1999
3-14).
—end—