Base Station Plug-Top Power Supply - Nortel Meridian Companion Installation And Maintenance Manual

Nortel meridian companion: installation guide
Hide thumbs Also See for Meridian Companion:
Table of Contents

Advertisement

Base Station plug-top power supply

P0725810 Issue 3.0
Station should not be installed in ducts, plenums, or hollow spaces
which are used to transport environmental air except where the duct,
plenum or hollow space is created by a suspended ceiling having lay-
in panels or tiles, in accordance with CE Handbook Rule 60-402.
Part no.
Color
Height
Width
Depth
Weight
Input voltage
Max. loop length (TCM)
Max. dc loop resistance (power
pairs)
Temperature
Relative humidity
If a plug-top power supply is required, use only the power supply
recommended for use with the Base Station. Other usage will
invalidate any approval given to this apparatus.
Part no.
Color
ac supply voltage
ac supply frequency
Sec. voltage
Sec. current
Temperature
Relative humidity
Height
Width
Depth
COMPANION 200 Installation and Maintenance Guide
Appendix B: Technical specifications 158
NT0P30DA-93 (A0403378)
Dolphin Gray
20 cm
32 cm
5 cm
less than 1 kg
12 to 50 V dc
1200 m
90 ohms (two-way)
+5°C to +40°C
5% to 85%(condensation may occur)
A0386334
Dolphin Gray
120 V
60 Hz
12 V
800 mA
+5°C to +40°C
5% to 85% (condensation may occur)
10 cm
10 cm
6 cm