6.10

Options for Stability Menu (3) - third half

Table 6-58
Stator Resistance Estimator Menu (3300) Parameters
Parameter
ID
Stator resistance est 3310
Stator resis filter
3320
gain
Stator resis integ
3330
gain
Table 6-59
Braking Menu (3350) Parameters
Parameter
ID
Enable braking
3360
Pulsation frequency 3370
Brake power loss
3390
VD Loss Max
3400
Braking constant
3410
NXGPro+ Control Manual
Operating Manual, A5E50491925A
Unit
Default
Min
Off
0.0
0.0
0.002
0.0
Unit
Default
Min
Off
Hz
275.0
100.0
%
0.25
0.0
pu
0.25
0.0
pu
1.05
0.0
Parameter Assignment/Addressing
6.10 Options for Stability Menu (3) - third half
Max
Description
Enable or disable the stator resistance estimator
function:
Off
On
This parameter is not implemented.
1.0
Stator resistance estimator filter gain.
1.0
Stator resistance estimator integral gain.
Max
Description
Enable or disable DFB.
Note: You must be aware of torque pulsations and
motor heating produced with this method.
5000.0
Torque pulsation frequency when DFB is enabled.
Adjust for a different torque pulsation frequency.
The control always recalculates the desired value
due to limited resolution. Adjust to avoid mechan‐
ical resonance frequencies.
50.0
Amount of high frequency losses at the onset of
braking. Affects the limit of the V
output braking voltage.
0.5
Max amplitude of the loss inducing voltage. Use
this to adjust the braking torque. Sets the maxi‐
mum loss limiting (V
10.0
Ratio of motor-induced losses to power absorbed
from load.
Always set this parameter to a value greater
than 1.0.
Setting this parameter higher increases V
voltage amplitude of losses in the motor and in‐
creases braking.
Exercise caution to prevent a motor thermal trip.
component of
q
) voltage amplitude.