Parameter Assignment/Addressing
6.19 Options for Multiple Configuration Files
Set active config file
Setup SOP config flags
Create new config file
Set
SOPConfigFileX_O
Table 6-102
Slave Setup and Configuration Parameters
Parameter
Multiple config files
Show active config file
Set active config file
Setup SOP config flags
Create new config file
Set SOPConfigFile1_O
Set SOPConfigFile2_O
Set SOPConfigFile3_O
Set SOPConfigFile4_O
Set SOPConfigFile5_O
Set SOPConfigFile6_O
172
Use this pick list to set the displayed file to be the active configuration
file.
This function overrides what is set in the SOP. Any change in the SOP
is checked against the file set in this function. Once a change in the
SOP is detected, that file will then be the active file. The keypad menu
setting is now ignored. This ensures no unintentional toggling of the
configuration files.
To switch back to the keypad file set it by this menu. If no change in the
SOP occurs, the keypad set configuration file will remain in memory.
Use this submenu for SOP flag configuration.
Use this function to save slave parameters to a file name you specify.
Use the drive keypad to enter the file name. To get to the alphanu‐
meric characters, use the left or right arrow keys to position the cur‐
sor. Use the up or down arrow keys to scroll to the desired letter or
number.
Use this function to map the name of the flag in the SOP
file, SOPConfigFileX_O (X = 1 to 8) to a name of a slave configu‐
ration file.
Once the SOP is running, and this flag is set to 'true', the configuration
file will be switched into memory. This is a method of switching
among multiple motors using one drive.
Select the file names from a pick list or create new files as described.
ID
Units
Default
9185
Off
9195
9196
defaults.sfg
9186
9197
9187
defaults.sfg
9188
defaults.sfg
9189
defaults.sfg
9190
defaults.sfg
9191
defaults.sfg
9192
defaults.sfg
Min
Max
Submenu
Description
Enable multiple configuration file opera‐
tion.
Display the current active configuration file
on the flash disk.
Set the displayed file to be the active con‐
figuration file on the flash disk.
Access menu for SOP flag configuration.
Create a new configuration file using the
numeric keypad.
Set the name of configuration file 1 to be
used with corresponding SOP flag 1.
Set the name of configuration file 2 to be
used with corresponding SOP flag 2.
Set the name of configuration file 3 to be
used with corresponding SOP flag 3.
Set the name of configuration file 4 to be
used with corresponding SOP flag 4.
Set the name of configuration file 5 to be
used with corresponding SOP flag 5.
Set the name of configuration file 6 to be
used with corresponding SOP flag 6.
NXGPro+ Control Manual
Operating Manual, A5E50491925A