Siemens SINAMICS PERFECT HARMONY GH180 Function Manual page 135

Hide thumbs Also See for SINAMICS PERFECT HARMONY GH180:
Table of Contents

Advertisement

1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0
Figure 6-5
Note
This feature is currently not implemented in NXGPro+
Table 6-55
Flux Table Menu (3131) Parameters
Parameter
ID
Flux Table Enable
3132
Flux @ 0.0% spd
3133
Flux @ 0.5% spd
3134
Flux @ 1.0% spd
3135
Flux @ 1.5% spd
3136
Flux @ 2.0% spd
3137
Flux @ 2.5% spd
3138
Flux @ 5.0% spd
3138
Flux @ 10.0% spd
3140
Flux @ 15.0% spd
3141
Flux @ 20.0% spd
3142
Flux @ 30.0% spd
3143
Flux @ 40.0% spd
3144
Speed at rated volts 3145
NXGPro+ Control Manual
Operating Manual, A5E50491925A
Flux Weakening
0
10 20 30 40 50 60 70 80 90 100 110 120 130 140
Flux Weakening
Unit
Default
Min
Off
1.00
0.15
1.00
0.15
1.00
0.15
1.00
0.15
1.00
0.15
1.00
0.15
1.00
0.15
1.00
0.15
1.00
0.15
1.00
0.15
1.00
0.15
1.00
0.15
%
100.00
50.00
Parameter Assignment/Addressing
6.8 Options for Stability Menu (3) - first half
Max
Description
Enables the flux shaping table
2.0
Flux demand at 0.0 percent of speed
2.0
Flux demand at 0.5 percent of speed
2.0
Flux demand at 1.0 percent of speed
2.0
Flux demand at 1.5 percent of speed
2.0
Flux demand at 2.0 percent of speed
2.0
Flux demand at 2.5 percent of speed
2.0
Flux demand at 5.0 percent of speed
2.0
Flux demand at 10.0 percent of speed
2.0
Flux demand at 15.0 percent of speed
2.0
Flux demand at 20.0 percent of speed
2.0
Flux demand at 30.0 percent of speed
2.0
Flux demand at 40.0 percent of speed
100.00
Percent of speed at which motor is at rated volts
Flux in PU
133