Advertisement

Figure 8-36
Multiple Motors on Long Cables using Single Drive
Parameters are the same as those required for standard cable impedance and if required output
filtering parameters. Refer to the Output Connection Menu (2900) for these parameters.
NXGPro+ Control Manual
Operating Manual, A5E50491925A
Lf
Lc
Cf
Lc
Advanced Operating Functions
8.24 Long Cable Applications
R
R
Ls
Cemf
Ls
Cemf