Evap Error Log Table - GE Datex-Ohmeda Aisys Carestation Reference Manual

Anesthesia machine
Table of Contents

Advertisement

Aisys

7.10.4 eVap Error Log table

Symptom
Agent Delivery check failed.
Cassette Not Latching
Compatibility failure: DCB hardware
No Liquid Level Indicator
Error Log Entry
ADB 10VA POWER ERROR
ADB VOLTAGE ERROR
AGENT LEVEL LOST
AGENT LEVEL OVER RANGE
AGENT LEVEL UNDER RANGE
CASSETTE LEVEL LOW
CASSETTE OVERFILL DETECTED
CASSETTE PRESSURE ERROR
CASSETTE PRESSURE ERROR
CASSETTE TEMPERATURE EEPROM FAILURE
CASSETTE TEMPERATURE FAILURE
CLOSED LOOP CONTROL FAILURE
COM ERROR VENT TO ACB
DCB RAM ERROR
FLOW MANIFOLD EEPROM FAILURE
INFLOW CHECK VALVE FAILURE
INFLOW OUTFLOW CROSSCHECK FAILURE
INFLOW OUTFLOW CROSSCHECK FAILURE RECOVERABLE
INFLOW ZERO 10VA POWER ERROR
INFLOW ZERO POINT ERROR
INSERT CASSETTE
INVALID CASSETTE ID
LOSS OF VAPORIZER USER SETTINGS
MAN CASS OVER UNDER TEMP
MANIFOLD TEMPERATURE EEPROM FAILURE
MANIFOLD TEMPERATURE FAILURE
OUTFLOW SCAV 10VA POWER ERROR
OUTFLOW ZERO POINT ERROR
OUTPUT FLOW LIMIT REACHED
PROP VALVE HTR 10VA POWER ERROR
VAP CASS TEMP SENSOR COMPAT FAIL
VAP FLOW METER BLK COMPAT FAIL
VAP SENSOR ERROR
VAP-MIXER FAN FAIL
VAPORIZER LOST MIXER FLOW
VAPORIZER SUBSYSTEM COMM FAILURE
VAP_CONDENSATION_CONDITION EXISTS
VAP ENHANCED CASSETTE TEMPERATURE FAILURE
VAP PORT ZERO READ BACK FAIL
7-84
eVap Troubleshooting Flowchart
See associated errors (Section 7.10.13)
(Flowchart 24) ADB Troubleshooting
(Flowchart 23) ACB Comm
(Flowchart 24) ADB Troubleshooting
(Flowchart 26) Power and Valves Troubleshooting
(Flowchart 24) ADB Troubleshooting
(Flowchart 24) ADB Troubleshooting
(Flowchart 24) ADB Troubleshooting
(Flowchart 24) ADB Troubleshooting
See other associated errors
(Flowchart 22) Leak and Cassette Troubleshooting
(Flowchart 21) Pressure Troubleshooting
(Flowchart 21) Pressure Troubleshooting
(Flowchart 25) Temperature Troubleshooting
(Flowchart 25) Temperature Troubleshooting
(Flowchart 20) Flow and Zero Troubleshooting
(Flowchart 23) ACB Comm
(Flowchart 24) ADB Troubleshooting
(Flowchart 21) Pressure Troubleshooting
(Flowchart 20) Flow and Zero Troubleshooting
(Flowchart 22) Leak and Cassette Troubleshooting
(Flowchart 22) Leak and Cassette Troubleshooting
(Flowchart 26) Power and Valves Troubleshooting
(Flowchart 20) Flow and Zero Troubleshooting
(Flowchart 24) ADB Troubleshooting
(Flowchart 22) Leak and Cassette Troubleshooting
(Flowchart 14) DU-ACB Communication
(Flowchart 25) Temperature Troubleshooting
(Flowchart 25) Temperature Troubleshooting
(Flowchart 25) Temperature Troubleshooting
(Flowchart 26) Power and Valves Troubleshooting
(Flowchart 20) Flow and Zero Troubleshooting
(Flowchart 20) Flow and Zero Troubleshooting
(Flowchart 26) Power and Valves Troubleshooting
(Flowchart 25) Temperature Troubleshooting
(Flowchart 21) Pressure Troubleshooting
See other associated errors
(Flowchart 26) Power and Valves Troubleshooting
(Flowchart 23) ACB Comm
(Flowchart 23) ACB Comm
(Flowchart 25) Temperature Troubleshooting
(Flowchart 22) Leak and Cassette Troubleshooting
(Flowchart 24) ADB Troubleshooting