show chassis fpc optical-properties pm-previousday

Syntax
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
List of Sample Output
Output Fields

Table 23: show chassis fpc optical-properties pm-previousday Output Fields

Field Name
PM
MIN
MAX
AVG
THRESHOLD (MIN) (MAX)
TCA-ENABLED (MIN) (MAX)
TCA-RAISED (MIN) (MAX)
Copyright © 2018, Juniper Networks, Inc.
show chassis fpc optical-properties pm-previousday fpc-slot fpc-slot
Statement introduced in Junos OS Release 15.1F6 and 17.1R1 on PTX3000 integrated
photonic line system.
Display performance monitors for the previous 24-hour period for the integrated photonic
line card (IPLC) module installed in the Flexible PIC Concentrator (FPC) or PIC slot.
fpc-slot—Slot number of the FPC or PIC in which the IPLC module resides
view
Enabling and Configuring Thresholds on the Integrated Photonic Line Card Performance
Monitors on page 45
Integrated Photonic Line Card Base and Expansion Module Overview on page 3
Understanding the Integrated Photonic Line Card Architecture on page 6
show chassis fpc optical-properties pm-previousday on page 138
Table 23 on page 137
lists the output fields for the
command. Output fields are listed in the approximate order in which
pm-previousday
they appear.
Field Description
Performance monitor
Minimum value measured
Maximum value measured
Average value
Threshold value set for the minimum and maximum values.
Threshold-crossing alert (TCA)set for the minimum and maximum values.
TCA is enabled.
TCA raised for the minimum and maximum values.
threshold.
Chapter 12: Operational Commands
show chassis fpc optical-properties
: TCA crosses the
Yes
:
Yes