Table 13: IPLC Threshold Crossing Alert Minimum and Maximum Values

TCA Identifier
Erbium-Doped Fiber Amplifier (EDFA) Input Power (for Both EDFAs)
edfa1-awg-high-tca
edfa1-awg-low-tca
edfa1-express-high-tca
edfa1-express-low-tca
edfa1-in-power-high-tca
edfa1-in-power-low-tca
edfa1-out-power-high-tca
edfa1-out-power-low-tca
edfa1-pump-current-high-tca
edfa1-pump-current-low-tca
edfa1-sig-power-high-tca
edfa1-sig-power-low-tca
Erbium-Doped Fiber Amplifier (EDFA) Output Power (for Both EDFAs)
edfa2-awg-high-tca
106
Description
Ingress EDFA pump AWG high TCA
Ingress EDFA pump AWG low TCA
Ingress EDFA pump express high
TCA
Ingress EDFA pump express low TCA
Ingress EDFA input power high TCA
Ingress EDFA input power low TCA
Ingress EDFA output power high TCA
Ingress EDFA output power low TCA
Ingress EDFA pump current high TCA
Ingress EDFA pump current low TCA
Ingress EDFA signal power high TCA
Ingress EDFA signal power low TCA
>
Egress EDFA pump AWG high TCA
Range Minimum/Maximum
Granularity
Default and Recommended Value
5s
390/440 mW
400 mW
5/15 mW
5 mW
390/440 mW
400 mW
5/15 mW
5 mW
0.5s
10/12 dBm
11 dBm
—38/—34 dBm
-35 dBm
20/21 dBm
20.5 dBm
—1/0.5 dBm
1s
10/300 mA
0.5s
10/12 dBm
11 dBm
—39/—35 dBm
—36 dBm
5s
390/440 mW
400 mW