Switching A Wavelength To An Optical Interface On A Remote Chassis - Juniper PTX3000 IPLC Features Manual

Packet transport router integrated photonic line system
Hide thumbs Also See for PTX3000 IPLC:
Table of Contents

Advertisement

See Also

Switching a Wavelength to an Optical Interface on a Remote Chassis

Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Switching Wavelengths on the IPLC to Optical Interfaces in a Local or Remote Chassis
For example, if you want to switch wavelength 1550.12 running on the local IPLC
module in slot 1 to the optical interface in slot 3, PIC 0, port 0:
[edit chassis fpc 1 optical-options]
user@host# set wavelength 1550.12 switch et-3/0/0
This step creates the association between the wavelength on the IPLC and the local
optical interface.
Verify that the configuration is correct. For example:
3.
[edit chassis fpc 1 optical-options]
user@host# show
wavelength 1550.12 {
switch {
et-3/0/0;
}
}
If the configuration is correct, save it.
4.
[edit chassis fpc 1 optical-options]
user@host# commit
Switching a Wavelength to an Optical Interface on a Remote Chassis on page 28
Understanding How to Configure the Integrated Photonic Line Card on page 9
Understanding the Integrated Photonic Line Card Architecture on page 6
This topic describes how to configure the IPLC module to switch a wavelength on the
and
ports to a compatible optical interface on a remote chassis.
ADD
DROP
NOTE:
For a list of compatible optical interfaces that are compatible with
the IPLC ports, see
Before you begin, complete the following tasks:
Install the optical interfaces and configure the wavelength number on the interface so
that it is compatible with the wavelength number on the IPLC. See
10-Gigabit or 100-Gigabit Ethernet DWDM Interface Wavelength
Install the IPLC module at the remote location and connect the
to the respective remote optical interfaces.
To configure the IPLC to switch a wavelength to an optical interface on a remote chassis:
Specify the slot of the local IPLC module and access the IPLC configuration hierarchy.
1.