Table 7: Optical ILA Threshold Crossing Alert Minimum and Maximum Values
TCA
Erbium-Doped Fiber Amplifier (EDFA) Input Power (for Both EDFAs)
edfa-ab-input-power
edfa-ba-input-power
Erbium-Doped Fiber Amplifier (EDFA) Output Power (for Both EDFAs)
edfa-ab-output-power
edfa-ba-output-power
edfa-ab-pump0-temperature
edfa-ba-pump0-temperature
edfa-ab-pump1-temperature
edfa-ba-pump1-temperature
Copyright © 2018, Juniper Networks, Inc.
NOTE:
You can configure 15-minute and 24-hour performance monitor TCA
thresholds on the optical ILA. When you configure the 15-minute and 24-hour
performance monitor TCA thresholds through the user interface of the optical
ILA, the optical ILA performs checking to ensure that the threshold values
are within valid ranges. Starting with Junos OS Release 17.1R1, the optical ILA
supports an inband optical supervisory channel that enables you to configure
these same performance monitor TCA thresholds through the Junos OS CLI,
in addition to the optical ILA user interface. However, when you configure the
optical ILA TCA thresholds through the Junos OS CLI, no range checking is
performed and if the thresholds are outside of the valid ranges, the
configuration is still accepted by Junos OS and the failure messages are
placed in the
/var/log/messages
the Junos OS CLI displays the previously configured threshold values when
you run the
show chassis fpc optical-properties pm-current
the Junos OS CLI. Range checking is imposed only when the optical ILA is in
Auto mode, which is the default setting.
Description
EDFA Input power (for both EDFAs)
EDFA Output power (for both EDFAs)
EDFA Pump temperature (for both EDFAs, 2 pumps
per direction)
Chapter 7: Configuring Performance Monitor Thresholds
directory of the PTX3000 router. However,
Range
Minimum/Maximum
12/—38 dBm
21/—13 dBm
30/20 Degrees C
command from
53

Advertisement

Table of Contents