Table 5: Iplc Threshold Crossing Alert Minimum And Maximum Values - Juniper PTX3000 IPLC Features Manual

Packet transport router integrated photonic line system
Hide thumbs Also See for PTX3000 IPLC:
Table of Contents

Advertisement

PTX3000 Integrated Photonic Line System Feature Guide
Table 4: IPLC Optical Performance Monitors (continued)
Performance Monitor
OSC estimated fiber loss
Line OUT VOA attenuation
EDFA Input power (for both EDFAs)
EDFA Output power (for both EDFAs)
EDFA Signal output power (for both EDFAs)
OCM power readings
Power monitor at ADD port
Power monitor at PT IN port

Table 5: IPLC Threshold Crossing Alert Minimum and Maximum Values

TCA
Erbium-Doped Fiber Amplifier (EDFA) Input Power (for Both EDFAs)
edfa1-awg-high-tca
edfa1-awg-low-tca
edfa1-express-high-tca
edfa1-express-low-tca
46
Each performance monitor supports:
15-minute and 24-hour binning
Low and high threshold levels as described in
Description
Ingress EDFA pump AWG high TCA
Ingress EDFA pump AWG low TCA
Ingress EDFA pump express high TCA
Ingress EDFA pump express low TCA
15 Min Bin
24 Hr Bin
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Table 5 on page
Range Minimum/Maximum
Default and Recommended
Granularity
Value
5s
390/440 mW
400 mW
5/15 mW
5 mW
390/440 mW
400 mW
5/15 mW
5 mW
Copyright © 2018, Juniper Networks, Inc.
TCA High
TCA Low
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
46.