Appendix E: Install the external housing

Important:
The cabling to the C4710/4720 is Category 5 Ethernet cabling. However, the cabling and C4710E/
4720E is submitted to the following safety restriction: The cabling and/or the C4710E/4720E may never
be exposed to over-voltages (for example, lightning). Therefore, the C4710E/4720E and cabling
associated with it may never be installed outdoors. However there is an exception: if installed in the
Outdoor Cabinet, and the Outdoor Cabinet is mounted against a wall and the cable is led directly
indoors, it is permitted.
Consult the work order, and perform the steps in this section as required:

Installing 4720 DAP with internal antennas

Installing a C4710 DAP in an external housing
Installing a C4710E DAP in an external housing with an external antenna
Mounting the cabinet on a wall
Mounting the cabinet on a pole
Installing 4720 DAP with internal antennas
Installing the Outdoor Box with 4720 DAP with internal antennas:
Installing the Outdoor Box with 4720 DAP with internal antennas
1. Open the Cabinet. To open the cabinet, use a screw driver that fits into the four
2. Remove the cover from the cabinet. The contents of the cabinet is shown in
SIP DECT Fundamentals
on page 232
on page 233
plastic screws at the front side of the cabinet. Unfasten the screws.
59: Contents of the box
on page 217
on page 228
on page 218.
on page 230
Figure