System configuration
SIP Line Gateway configuration
There are no specific SIP DECT configuration requirements for SIP Line. For information about
installing and configuring SIP Line Gateway, see Avaya SIP Line Fundamentals,
NN43001-508.
When configuring SIP Line Gateway for use with a SIPL configuration, ensure that you
configure the following parameters:
• While enabling the SIP Line Service and configuring the root domain, enter a User agent
DN prefix (which is required for UEXT SIPL configuration) and root domain name that are
the same as the values you entered for the SIP DECT domain name
Settings
• While Configuring SIP Line gateway node, enter the same domain name (case-sensitive)
as you entered for SIP DECT and SIP Line service, and ensure that the SIP LINE Gateway
local SIP port corresponds with the Proxy port.
Configuration of Universal Extension on a Call Server
Universal Extension (UEXT) redirects incoming calls to the DAP. Key 0 corresponds with the
DN, configured on the DAP. Key 1 HOT U is the same number with a User agent DN prefix
configured for SIP Line.
Use LD 15 to configure station control password length before you configure the UEXT for SIP
Line users.
Table 16: LD 11: Configure station control password length
Prompt
REQ
TYPE
CUST
SCPL
Use LD 11 to configure UEXT.
Packages 139, 415, and 417 must be enabled on the Call Server.
106
SIP DECT Fundamentals
The DN appears on the handset display. The status of the subscription record
changes from Enabled to Subscribed.
For information, see
Subscription management
on page 96.
Response
CHG
FFC
n
x
Comments? infodev@avaya.com
on page 123.
Description
FFC_DATA
n = customer number
x = the maximum length of the password