Avaya CS 1000 Fundamentals page 101

Sip dect fundamentals
Hide thumbs Also See for CS 1000:
Table of Contents

Advertisement

Basic (simple) SIP DECT configuration with Communication Server 1000 SIP Line Gateway
8. Select the Email Settings tab
9. Enter a value next to SMTP Server with the DNS name or the IP address of your
10. Select the Send alarm emails check box , which enables SIP DECT to send email
11. Fill the field next to Email addresses with one or more destination email
12. Enter a value next to Email from with the email address of the originator.
13. Fill in the two boxes after Channel Occupation. In the Threshold box, specify the
14. Select the Alarms Settings tab. Select Alarm notification type.
15. Fill in the box next to Alarm reaction time with the hours as an interval to send
16. Select the Archive Settings tab.
17. Select the Email nightly created archive check box to automatically receive
18. Enter a value next to Email addresses with one or more destination email
19. Select the days to receive archives, the date to stop sending archives, and the
20. Select the Miscellaneous Settings tab.
21. Optionally, enter HTTP execution time out. HTTP execution time out (specified in
SIP DECT Fundamentals
SMTP mail server.
Email messages can be sent automatically if a DAP fails or if the channel occupation
threshold is exceeded for more than a specified number of seconds. Automatic
email messages can be sent only if the DAP controller or manager is running, and
the PCR service is running on the DAP controller or manager PC.
If you enter the DNS name of your SMTP Server, ensure that the DNS server
address is configured for the network connection on the DAP Controller.
messages to the SMTP Server.
addresses.
Normally, the SMTP server does not verify the email address of the originator. This
means you can enter any email address in this field.
percentage. In the Time box, specify a time in seconds.
Channel Occupation defines the conditions for generating an email on DAP channel
occupation. If the channel occupation is higher than the percentage of the available
channels for a specified time period, an email is generated. The threshold is
specified in percentage, the time is specified in seconds.
email messages.
The default Alarm reaction time is 24 hours. This means that the minimum interval
between two alarm email messages is 24 hours; after the system sends an alarm
email, 24 hours must pass before the system can send another alarm email. Enter
0 (zero) if you want alarm email messages to be sent immediately after an alarm
event occurs.
archives for each email.
addresses.
maximum size of the attached archive.
seconds) is a guarding timer for the ASP scripts. For example, if the ASP Web pages