P1.Xxx Basic Parameters - Delta ASDA-B3 Series User Manual

Hide thumbs Also See for ASDA-B3 Series:
Table of Contents

Advertisement

ASDA-B3

P1.xxx Basic parameters

P1.000▲
Default: 0x1042
Unit: -
Format: HEX
Settings:
X
Pulse type
Y
Filter width
X: pulse type
0: AB phase pulse (4x)
1: clockwise and counterclockwise pulses
2: pulse train + sign
Z: logic type
0: positive logic
1: negative logic
Digital circuits use 0 and 1 to represent the high and low voltage levels. In positive logic, 1
represents high voltage and 0 represents low voltage; in negative logic, 1 represents low voltage
and 0 represents high voltage.
Example:
Positive logic
External pulse input type
Control mode: PT
Setting range: 0x0000 to 0x31F2
Data size: 16-bit
Z
Logic type
U
Filter width
Negative logic
Parameters
Address: 0100H
0101H
8
8-33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents